KOLIBRI AUTOMATIC BILL COUNTER FAQ
KOLIBRIâ„¢ AUTOMATIC BILL COUNTER
PRODUCT SPECIFICATIONS

Type: Bill Counter

Loading Style: Back

Display: Large LED Screen

Recognizes Denominations: No

Counting Speed: 1,500 bills/min

Hopper Capacity: 200 bills (uncirculated)

Stacker Capacity: 200 bills (uncirculated)

Unit Weight: 10.6 lbs (4.8 kg)

Unit Dimensions (L x W x H): 11.4″ x 9.8″ x 6.9″

Counterfeit Detection: UV, MG, IR

Modes: Add, Batch, Add+Batch

On-screen Report: No

Allows Print: No

The Kolibri Bill Counter is offered exclusively on Amazon. View the latest information and sales page here: Kolibri Bill Counter.

  • The Kolibri Bill Counter serial number is a string of numbers and letters unique to your unit that helps us identify your product and look up information regarding this specific product. Please look to the underside of your unit for the serial number.

  • An example serial number is shown below. The format will always be the same, 6 numbers, followed by ‘NKOL’ and ending in 5 numbers: ######NKOL#####


             

  • The below cleaning guide is available as a printable document listed in the Documents section of this page.
  • First, make sure the unit is turned off and unplugged
  • Perform the cleaning of each sensor, one step at a time (a to c), and check after each step if this resolves the issue. If it does not, proceed to the next cleaning step

(a) Wipe away dust with a soft microfiber cloth or a bristle brush

(b) Clean the sensors using a can of compressed air

(c) Clean with a cotton swab lightly moistened with isopropyl alcohol – gently wipe the sensors with the swab.

Refer to the photos below showing the location of the Kolibri Bill Counter sensors. For each sensor, follow the steps as described above.

Locate the hopper sensor as shown below. This sensor is at the top of the unit, where money is placed for counting.


Locate the two sensors in the hopper of the unit (as shown in the image below), these are the Hopper Sensors.

Locate the two counting sensors, which are underneath the display panel as shown below. Note there are two counting sensors (left and right). Each of these sensors has an upper and lower component.

Locate the magnetic sensor, which looks like a metal bar, and is underneath the display panel as shown below.

  • Kolibri suggests that the user cleans the unit at least once per week. For heavy use locations and operations, the user may clean the unit daily to avoid heavy buildup that may cause improper operation. When the unit is not in use, Kolibri suggests that the user covers the unit with a dust cover (included).

There are 3 main reasons why a unit would jam:

  • Bills are very worn, torn, ‘soft’, or in folded. In this situation, the bills may crumple in the bill path and get stuck. To resolve it, correct or remove the bills if they are severely wrinkled, damaged or folded.

  • Bills are fed incorrectly into the unit. In this situation, the bills may enter the bill path crookedly and the unit is prone to jamming by bad feeding and may damage the unit and the notes as they pass through. To resolve it, follow the bill loading technique bellow. This guide is also available as a printable document listed in the Documents section of this page.

Square the bill stack as shown below:

  1. Place the bill stack almost perpendicular to the screen with the bottom of the stack touching the bill guide plate.

2. Flip the bill stack towards the rear of the machine so the stack is now leaning against the bill guide plate.

3. Flip the bill stack towards the rear of the machine so the stack is now leaning against the bill guide plate.

4. Bill feeding will automatically begin.

Different angle:

The adjustment of the fed gap is altered due to transit or over time normal wear and tear. In this situation, multiple bills can enter the bill path at once, or with an angle which lead to errors and jamming. To learn how to adjust the feed gap, please refer to Section 6: What is a feed gap? How do I adjust it?

  • The feed gap is the actual height of the bill feed path, and should be tuned to just about the thickness of a single bill. If the feed gap is too wide, the user may experience a high amount of dbL (DOUBLE) and CHn (CHAIN) errors which are caused by more than one bill entering the scanning path at one time. If the feed gap is too tight, the unit may not be able to pass bills into the scanning path, or catch on bills and tear them.
  • For feed gap adjustment procedure, a printable document is available in the Documents section of this page. The following steps are the procedure for adjusting the feed gap:

To adjust the feed gap properly, you will need a philips screwdriver (not included).

  1. Ensure the machine is turned off.
  2. Locate the feed gap adjustment knob (green) and the fixing plate screw (green circle) at the back of the machine (loosen before performing any adjustment).

3a. If more than one bill is being pulled into the feed mechanism (Double/Chain errors), turn the knob clockwise to decrease the feed gap. Adjust 1 turn, then retest the machine to see if the problem is corrected. Repeat as necessary.

NOTE: If the feed gap is adjusted too narrow, chain error, bill jams and tears can occur.

3b. If Chain error or bill jamming is seen on the input, turn the knob counterclockwise to increase the feed gap. Adjust 1 turn, then re-test the machine. Repeat as necessary.

NOTE: If the feed gap is adjusted too wide, double and half errors can occur.

4. Fix the adjusted position by tightening (clockwise) the fixing plate screw.

IMPORTANT NOTE: The Kolibri Automatic Bill Counter’s feed gap adjustment can be sensitive during adjustments. DO NOT overturn each adjustment or you may overshoot the optimum gap. We recommend testing with a stack of bills after each adjustment turn.

The Kolibri Bill Counter’s feed gap adjustment can be sensitive during adjustments. Do not overturn each adjustment or you may overshoot the optimum gap. We recommend testing with a stack of bills after each adjustment turn.

If, after adjusting the feed gap, this does not resolve the issue, please see the support section on the Kolibri USA website at www.kolibriusa.com, or contact Kolibri Support at support@kolibriusa.com for further troubleshooting.

  • The Kolibri Bill Counter provides UV (ultraviolet) and MG (magnetic) anti-counterfeit feature detections. To learn more about detection techniques, please refer to Section 9: What do MG, UV stand for? What’s the difference?
  • There are 2 main counterfeit detection techniques used in most bill counters:
  1. Magnetic Feature Detection (MG) – US currency uses specific magnetic ink at exact locations to provide a unique magnetic signature on each denomination note. By scanning each bill for the presence and location of these features, the Kolibri Automatic Bill Counter is capable of detection the minute magnetic signals present on these bills and will flag any notes that do not have these features present, in the correct locations. Certain counterfeit notes do not have the same features and will be rejected by the Kolibri Automatic Bill Counter as “E02”.
  2. Ultraviolet Feature Detection (UV) – Certain features are hidden to the naked eye on all US currency. In order to detect these features, the Kolibri Automatic Bill Counter has special ultraviolet emitters and sensors capable of detecting the exact ultraviolet anti-counterfeit features built into each denomination note. The Kolibri Automatic Bill Counter scans each bill for the presence and accuracy of these features and fails any bills not meeting these criteria as “E01”.
  • There are a few reasons that a genuine bill may be flag as suspect. If bills are worn, bent, torn, or crumpled, the anti-counterfeit features needed to verify a bill as genuine may be compromised. For example, the magnetic ink on a note may wear over time or heavy use, reducing the magnetic response to below detection thresholds.
  • If sensors are dirty or damaged, the unit will not be able to detect the necessary anti-counterfeit features needed to verify currency as genuine.
  • Another possible reason is that the detection sensors may be incorrectly calibrated, lost reference, or be under operating conditions that cause false positives. In order to reduce these error types, it is advised to operate the unit out of direct sunlight and reduce interference that may cause sensor errors. If this occurs frequently under normal operation, please contact Kolibri support for troubleshooting or service.
  • One of the most common reasons for miscounting is improper loading of the currency to be counted. In most cases the Kolibri Bill Counter will display an error, like “CHn” to reload the currency.
  • The second most common reason for improper counting is poor maintenance of the unit. Each sensor needs to be clean and free of debris to operate correctly.
  • In rare cases, electromechanical failure of the unit will cause all notes to be sensed incorrectly. For frequent, repeatable improper denomination errors, please contact Kolibri Support for repair.
  • Yes, the Kolibri Automatic Bill Counter processes bills in customized amount called Batch Mode. Predetermined note sets are created using this mode in quantities of 100, 50, 25, 20 or 10 bill batches. To use Batch mode, press the BAT button and select one of the preset batch amounts. Each press of the BAT button will toggle to a preset amount. The Batch indicator light will illuminate when Batch mode is active.
  • Yes, the Kolibri Automatic Bill Counter keeps count of bills added called ADD Mode. To use ADD mode, press the ADD button and the unit will count multiple stacks of bills while keeping track of the total amount of bills counted. The “ADD” indicator light will illuminate when ADD mode is active.
  • No, the Kolibri Automatic Bill Counter only counts the number of bills. If you need to sum the value or count multiple denominations at one time, you need a Bill Reader like the Kolibri Domino, KBR-1500, or Kolibri Signature. Bill readers use advanced sensing to determine the denomination of the notes being scanned.
  • The Kolibri Bill Counter uses a F2AL250V 20mm Length by 5mm Diameter fuse above the AC power inlet (where the power cord inserts to the back of the unit.) Check this fuse if the unit does not power on. If replacing the fuse does not solve power-on issues, please contact Kolibri Customer Service.
  • The warranty of this unit covers manufacturing defects, and unit related failures that occur during normal operation following the specific guideline set forth in the user manual. Kolibri is not responsible for errors or failures caused by improper use, mishandling, liquid spills on the unit, foreign object damage, units which have been opened/tampered with, or damage caused by improper maintenance, storage, or transportation.
  • Please contact Kolibri support through our webpage and provide a description of the failure.

Required information include

  • Your contact information so we may respond
  • The product serial number – To find your serial number refer to Section 2: Where is the serial number for my unit? What does it look like?
  • The subject of your request

A brief description of the failure that has been encountered

  • Contact Kolibri Support through our webpage at https://kolibriusa.com/contact/ and create a support ticket. The customer service representative assigned to your ticket will respond with troubleshooting techniques, or arrange for an on-site repair at our facility.
USER MANUAL
FEED GAP ADJUSTMENT PROCEDURE
CLEANING PROCEDURE
BILL LOADING PROCEDURE